Fm 200 is included in nfpa 2001 under the generic name hfc 227ea and has been evaluated and.
Fm 200 fire suppression system design calculation.
80 of fm 200 fire fighting effectiveness is achieved through heat absorption and 20 through direct chemical means action of the fluorine radical on the chain reaction of a flame.
Free download now fm 200 calculation program from mep work.
The ansul fm 200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a b and c fires.
Our clean agent fire protection system which includes the use of hfc 227ea and fm 200 leaves no residue and doesn t require costly clean up unlike sprinklers and other fire protection systems and it discharges in 10 seconds or less extinguishing a fire quickly and.
Total number of fm 200 cylinder.
When used at standard design concentrations it is safe for occupied spaces.
Fm 200 1 1 1 2 3 3 3 heptafluoropropane cf3chfcf3 is a colorless odorless gas low in toxicity electrically non conductive leaves no residue and is an extremely effective fire suppression agent.
After an fm 200 system discharge the fm 200 cylinder s should be returned to an authorized chemetron filling location for recharge.
The primary extinguishing mechanism of fm 200 is heat absorption with a secondary chemical contribution from the thermal decomposition of fm 200 in the flame.
When properly designed the fm 200 system will suppress surface burning fire in class a b and c hazards.
After receiving the fire signal fm 200 is discharged totally from the cylinders within 10 seconds to fill up the space uniformly at the design concentration to extinguish the fire.
Complete suppression using fm 200 has the following.
Safe for use in occupied areas at the design concentration the system helps protect critical infrastructure and delivers effective asset protection.
Heptafluoropropane more commonly known as fm 200.
What is an fm 200 fire suppression system.
Fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems.
Also known as hfc227ea this is a waterless fire protection system that works wonders when under pressure.
Within 10 seconds it will discharge and suppress a fire immediately.
This calculation tool is intended for use in developing approximate estimates of the material and equipment budgeting purposes.
The software is designed b y mostafa elwakeel and he gave us the rights to publish it.
Ul ulc fmrc require multiple tiers of nozzles for heights above 16 0 4 88 m.
Fm 200 systems using concentrations below 6 25 are not ul ulc listed nor factory mutual approved.
Fm200 calculation program version 1 0 is a software for calculating the weight of fm 200 gas needed for fire suppression system.
For speed in suppressing fires reducing damages saving on floor space and allowing visibility fike is the clear choice.